Smith's Products
Surface Prep

Green Clean Pro
Biodegradable Non-Corrosive Liquid Cleaning & Etching SolutionProduct Quantity | 2 gal |
Colours | Green Hue |
Working Time | 20 Minutes |
Application Time | 20 Minutes (DO NOT DRY) |
SF Or LF | 400-500 SF |
Area Or Depth | /unit |
Floor Or Wall | Floors & Walls |
Interior or Exterior | Interior & Exterior |
Compressive Strength (PSI) | N/A |
TF | Tack Free |
RC | Recoat |
FT | Foot Traffic |
LT | Light Traffic |
DT | Dry Through |
FC | Full Cure |
HFT | Heavy Foot Traffic (Forklift) |
VT | Vehicular Traffic |
FUT | Full Traffic |
-
A biodegradable acidic detergent solution developed to prepare a concrete substrate by both cleaning and producing a moderate surface texture. Concrete treated with Smith’s Green Clean Pro results in a neutral Ph by simply pressure washing or flushing with water per application instructions
-
Produce a moderate texture on concrete
-
Biodegradable
-
User friendly
-
Non-corrosive
-
Low odour
-
RECOMMENDED USE: Preparation of a concrete surface for the application of Smith’s Color Floor, Color Wall and Color Accents
-
NOT RECOMMENDED FOR: Coating removal including paint, sealer and other film forming products
-
1) Remove paint, adhesives and loose particles from the intended application surface
-
2) Liberally apply Smith’s Green Clean Pro to a 20x20 feet section of the substrate or smaller with a pump up sprayer or dip and roll method with a ½ inch nap roller cover. Wetting the intended treatment area with water is recommended for application in hot weather or direct sun exposure
-
3) Allow the Green Clean Pro to remain on the substrate for 20 minutes. Do not allow material to dry on the substrate. Mist water via hose or pump up spray to keep treated area from drying
-
4) For exterior application, utilize a 12,000 work units* pressure washer in conjunction with a 0 degree rotating nozzle tip to remove the Smith’s Green Clean Pro with overlapping line patterns. For interior surface preparation, agitate Smith’s Green Clean Pro utilizing a floor buffer (small area) or an auto-scrubber (large area) equipped with brush attachments while rinsing with clean water
-
5) Extract material utilizing a wet/dry vacuum or by lowering the squeegee uptake bar on the auto-scrubber. Continue to flush and agitate the substrate until the rinse water is clear. M285) Allow surface to dry
-
6) Perform a “Tape Test”
-
Applied via pump up sprayer or dip and roll via ½ inch nap cover on a roller cage
-
Safety Data Sheet | SDS
Download PDFTechnical Data Sheet | TDS
Download PDFVisit Smith's Website
Visit Website